HVAC condensate drainage
A flexible ¾″ P-trap for HVAC and air conditioner condensate lines. It clamps on with no primer or cement, and you can squeeze it to clear a clog.
A plugged condensate trap usually means a brush, a wet vac or a saw. This one is molded from flexible PVC, so you can squeeze it to break sediment loose, or back off two clamps and pull it out whole.
Hand pressure breaks sediment loose and gets the line flowing
Keeps the system’s fan from moving air through the drain, so the pan keeps draining
Back off the stainless clamps to pull it out. It goes back on the same connections
No ports to open. Squeeze the body by hand to break sediment loose and get the line flowing.
No primer or cement. The system goes back in service as soon as it’s clamped and the trap is filled with water.
The flexible body works into low-clearance attic units, tight closets and over a secondary pan.
No solvent odor left in the home and nothing to wipe off a finished floor.
¾″ Flexible Condensate P-Trap for HVAC Systems and Air Conditioners
Pipe or hub, end by end. Each end has a bushing. Leave it in to fit ¾″ PVC pipe, or take it out to fit a ¾″ hub.
Hold the new trap up to the existing line to check the fit. Mark lines on the pipe matching both ends of the new trap.
Measure ¾″ down from each dry fit mark and make a second mark. This is where you cut.
Switch off power at the HVAC unit or at the circuit breaker.
Use a PVC pipe cutter or hand saw to cut on the second mark at each end. Remove the old trap.
Use a utility knife or deburring tool to scrape away plastic fragments and burrs.
Loosen the screw on each clamp. Remove the included bushing if you’re installing over a hub.
Slide each end of the trap over its pipe or hub. Hand tighten each clamp with a nut driver or screwdriver.
Pour 3 to 6 ounces of tap water directly into the line above the trap.
Turn the power back on and check for leaks.
Tools: tape measure, marker, PVC pipe cutter or hand saw, utility knife or deburring tool, and a nut driver or screwdriver.
| Part | CT-075 ¾″ Flexible Condensate P-Trap for HVAC Systems and Air Conditioners |
| Fits | ¾″ PVC pipe (bushing in) or ¾″ hub (bushing out), at each end |
| Material | Elastomeric polyvinyl chloride |
| Clamps | Stainless steel |
| Temperature | -30°F minimum; 140°F maximum (intermittent) |
| Size | 1.30″ x 5.00″ x 8.12″ |
| Use | Drain, waste and vent only |
| Case quantity | 10 |
| Made in | USA |
Each end fits ¾″ PVC pipe with its bushing in, or a ¾″ hub with the bushing out, so one end can go on a hub and the other on pipe. Not sure what you have? Reach out.
Squeeze the body by hand to break sediment loose. If that isn’t enough, back off the clamps with a nut driver, pull the trap out whole, clean it and reinstall it on the same connections. Then prime it again, the same way you did when you installed it.
Yes. After you install it, pour 3 to 6 ounces of tap water into the line above the trap. The water seal keeps the system’s fan from moving air through the drain, so condensate can drain out of the pan.
No. The trap clamps on with stainless steel clamps, so there’s nothing to brush on and no cure time.
Yes. It’s made for HVAC, air conditioner and furnace condensate drain lines in residential and light commercial systems.
Down to -30°F, and up to 140°F for short periods.