QwikSeal is a single molded gasket with an internal pipe stop, secured by one clamp. Nothing to assemble in the trench, and the numbers to back it on a submittal.
The seal is one molded EPDM gasket. There is no separate hub, sleeve or band set to fit together in the hole, and no cure time.
Gasket conforms to ASTM C923 and is performance tested to Section 7: straight alignment, 7° axial deflection and shear load, all with no leaks.
SAE J1508 Type HD clamp, every component 316 stainless steel to ASTM A240. 60 in-lb installation torque, 150 in-lb ultimate.
4″, 6″ and 8″ laterals in SDR-35 or SCH 40, into mains 8″ and larger. Green is SDR-35, grey is SCH 40, so the crew grabs the right one.
Host pipe
Concrete, clay, solid-wall PVC and corrugated plastic. The lateral is 4″, 6″ or 8″. The main is 8″ and larger, with no upper limit on concrete, clay or solid-wall pipe.
8″ to 24″ host. Soil-tight connection.
Solid wall, profile and closed profile. 8″ and larger.
Core with a diamond bit. 8″ and larger.
Pipe and manhole bases. 8″ and larger.
Corrugated pipe: QwikSeal makes a soil-tight connection in corrugated mains from 8″ to 24″ (10″ to 24″ for QS-6, 15″ to 24″ for QS-8). Hydrostatic ratings below apply to concrete, clay and solid-wall pipe.
Metal pipe: not recommended for connection to metal pipe.
The lineup
Pick the lateral size and the lateral pipe type. Green QwikSeals fit SDR-35 (and SDR-26) laterals; grey QwikSeals fit SCH 40. Each part lists the smallest main it fits and the hole to core.
Host pipe: concrete, clay or solid-wall plastic at the size shown and larger; corrugated plastic at the range shown.
| Part No. | Lateral (inlet) | Color | Concrete, clay, solid-wall | Corrugated | Core hole |
|---|---|---|---|---|---|
| QS-4 | 4″ SDR-35 | Green | 8″ and larger | 8″ to 24″ | 5″ |
| QS-4S40 | 4″ SCH 40 | Grey | 8″ and larger | 8″ to 24″ | 5″ |
| QS-6 | 6″ SDR-35 / SDR-26 | Green | 10″ and larger | 10″ to 24″ | 7″ |
| QS-6S40 | 6″ SCH 40 | Grey | 10″ and larger | 10″ to 24″ | 7″ |
| QS-8 | 8″ SDR-35 / SDR-26 | Green | 15″ and larger | 15″ to 24″ | 9″ |
Engineering data
Performance tested to ASTM C923 Section 7 on a 24″ manhole base, plus hydrostatic testing of each part installed in its host pipe. Full data on the Technical Data Sheet below.
| Hardness, Shore A | 51 ASTM D2240 |
| Tensile strength | 1,590 psi ASTM D412 |
| Elongation at break | 660% ASTM D412 |
| Tear strength | 192 ppi ASTM D624 |
| Water absorption | +8.23% wt. ASTM D471 |
| Compression set | 19.2% ASTM D395 |
| Chemical resistance, 48 h | 1N sulfuric / hydrochloric acid ASTM D543, no weight loss requirement |
| Ozone resistance | No cracks ASTM D1149, 50 pphm, 100 h at 40°C |
| Specific gravity | 1.19 ASTM D297 |
Typical values from the QwikSeal Technical Data Sheet.
Approximate protrusion of the seal into the main pipe, by main diameter. Useful for hydraulics, jetting and CCTV clearance.
| Main | Protrusion |
|---|---|
| 8″ | 0.88″ |
| 10″ | 0.67″ |
| 12″ | 0.55″ |
| 15″ | 0.43″ |
| 18″ | 0.35″ |
| 24″ | 0.26″ |
| 30″ | 0.21″ |
| 36″ | 0.17″ |
| 42″ | 0.15″ |
| 48″ | 0.13″ |
| 54″ | 0.12″ |
| 60″ | 0.10″ |
| Main | Protrusion |
|---|---|
| 10″ | 1.43″ |
| 12″ | 1.30″ |
| 15″ | 0.87″ |
| 18″ | 0.71″ |
| 24″ | 0.52″ |
| 30″ | 0.41″ |
| 36″ | 0.34″ |
| 42″ | 0.29″ |
| 48″ | 0.26″ |
| 54″ | 0.23″ |
| 60″ | 0.20″ |
| Main | Protrusion |
|---|---|
| 15″ | 0.87″ |
| 18″ | 0.71″ |
| 24″ | 0.52″ |
| 30″ | 0.41″ |
| 36″ | 0.34″ |
| 42″ | 0.29″ |
| 48″ | 0.26″ |
| 54″ | 0.23″ |
| 60″ | 0.20″ |
Installation
Everything happens from outside the main. The full 13-step instructions, including the stub-and-fitting, bell-end and street-fitting methods, are in the installation sheet below.
Core a perpendicular hole in the main: 5″ for a 4″ lateral, 7″ for 6″, 9″ for 8″. File or sand the edge clean of burrs.
Remove the clamp, fold the QwikSeal and push it through the opening. Unfold it and pull up until it stops against the inside of the pipe.
Measure from the pipe stop to the top edge, add the fitting depth, and cut the stub to length. Bevel the leading edge and lubricate.
Start the stub by hand, drive it to the pipe stop with a block and hammer, then install the clamp at 60 in-lb.
From the field
“They were having trouble yesterday putting in a competitor’s product and after two hours of screwing around with it, they gave up for the day. I showed up this morning and within five minutes, they had the QwikSeal installed. Both the contractor and the county were extremely happy with the results, and they asked me to make sure all of our distributors were stocking the QS-4, QS-6 and QS-8.”
C.P. Ward Contractors · cpward.com
Ordering
Everything you need to order for a tap: the QwikSeal, plus the hole saw (plastic pipe) or coring bit (concrete and clay) that matches the lateral size.
| Part No. | Item | Pairs with |
|---|---|---|
| QS-4 | QwikSeal, 4″ SDR-35 lateral, green | 8″ and larger main · 5″ core |
| QS-4S40 | QwikSeal, 4″ SCH 40 lateral, grey | 8″ and larger main · 5″ core |
| QS-6 | QwikSeal, 6″ SDR-35 / SDR-26 lateral, green | 10″ and larger main · 7″ core |
| QS-6S40 | QwikSeal, 6″ SCH 40 lateral, grey | 10″ and larger main · 7″ core |
| QS-8 | QwikSeal, 8″ SDR-35 / SDR-26 lateral, green | 15″ and larger main · 9″ core |
| QS-5x4HS | Hole saw, 5″ OD × 4″ deep, with arbor | QS-4, QS-4S40 · plastic pipe |
| QS-7x4HS | Hole saw, 7″ OD × 4″ deep, with arbor | QS-6, QS-6S40 · plastic pipe |
| QS-9x4HS | Hole saw, 9″ OD × 4″ deep, with arbor | QS-8 · plastic pipe |
| QS-5x14CB | Coring bit, 5″ OD × 14″, diamond abrasive | QS-4, QS-4S40 · concrete and clay |
| QS-7x14CB | Coring bit, 7″ OD × 14″, diamond abrasive | QS-6, QS-6S40 · concrete and clay |
| QS-9x14CB | Coring bit, 9″ OD × 14″, diamond abrasive | QS-8 · concrete and clay |
Hole saws without arbor, the QS-ARBOR-S arbor and the QS-ADAPTER coring-machine adapter are listed on the Fernco Hole Saws sheet below.
One drawing per part, for submittals and spec packages.
Technical data, submittal sheet, sell sheet, installation instructions and tools.
Technical data · Gasket, clamp, ASTM C923 tests, protrusion
Start with the lateral. A 4″ lateral takes QS-4 (SDR-35) or QS-4S40 (SCH 40); 6″ takes QS-6 or QS-6S40; 8″ takes QS-8. Green is SDR-35, grey is SCH 40. Then check the main meets the minimum size for that part: 8″ for the 4″ parts, 10″ for the 6″ parts, 15″ for QS-8.
5″ for a 4″ lateral, 7″ for 6″, 9″ for 8″. Use a Fernco hole saw on plastic pipe and a diamond coring bit on concrete or clay.
On corrugated mains QwikSeal makes a soil-tight connection, in hosts from 8″ to 24″. The hydrostatic and ASTM C923 ratings on this page apply to concrete, clay and solid-wall plastic pipe.
It is not recommended for connection to metal pipe.
Not for concrete, clay or solid-wall pipe. If you can core the hole, the seal fits; the protrusion table above runs to 60″ mains. Corrugated hosts are 8″ to 24″.
No. The seal is compressed by the clamp against the lateral and seats on the inside wall of the main. Lubricate the seal and stub, drive to the pipe stop, and clamp at 60 in-lb.
QwikSeal is tested to ASTM C923 Section 7 at 7° of axial deflection and under a shear load of 150 lb per nominal inch of pipe ID, both at 10 psi with no leaks.
Yes. The Engineering Specifications sheet above is a one-page submittal with project, engineer and contractor fields, the gasket data and the clamp specification.
Tell us the main material and size, the lateral size and pipe type, and our team will confirm the right QwikSeal and the coring tool to go with it.