Menu
Large diameter sewer connections
A proven solution pros have relied on for decades to connect, repair and rehabilitate large diameter sewer pipe. Engineered around the measured outside diameters of your pipes, for connections standard sizes don’t cover.
What they’re for
Large diameter work doesn’t always line up with a catalog size. When a connection falls outside our standard line, our team can engineer a coupling around the measured outside diameter of each pipe, for repairs, alterations and rehabilitation of large diameter sewer pipe.
Engineered around the measured outside diameter of each pipe.
A wide flexible PVC body with high torque stainless steel clamps, tightened up to 120 in-lb.
Clay, concrete, cast iron, ductile iron, plastic or fiberglass, with a bushing system for O.D. differences from 1¼″ to 12″.
Available non-shielded, or as a Strong Back RC shielded coupling with a stainless steel shield.
Our standard couplings run up to 27″ nominal, for pipe up to about 33.9″ O.D., and our Strong Back HTRC corrugated pipe couplings run up to 60″. If your connection fits one of those, start there. If it doesn’t, reach out to our team about a custom coupling.
Standard Couplings finder › Strong Back HTRC corrugated couplings ›
Versions
The non-shielded coupling is the right fit for many jobs. Where burial depth, soil conditions or the project spec call for added support against earth loads, settlement and shear, the Strong Back RC stainless steel shield wraps the coupling and helps keep the pipe in line against shear forces from soil compaction, shifting and settling.
Conditions vary by region and job. Always follow the project specifications and your local codes and regulations when choosing between the two.
The flexible PVC Large Diameter Coupling with high torque stainless steel clamps. Coupling clamps tighten to 120 in-lb.
The same coupling with a stainless steel shield over the joint for added strength and support. Shield clamps tighten to 60 in-lb.
Custom builds
A coupling we built to a job’s measured outside diameters, shown as a dimensional drawing and as an example of the submittal that goes with it.
Two pages for the same 44.00″ × 38.30″ build: product data, materials, installation summary, review block and the dimensional drawing
How to order
Get the outside diameter of each pipe. On large pipe, wrap a tape around it and divide the circumference by 3.1416.
Send both O.D.s, the material of each pipe and the application.
We review the connection and follow up on a custom coupling, and any reducer bushings, for your job. No minimum order.
Custom parts are non-refundable, so measure carefully.
Installation
Install the reducer bushing near the end of the small pipe, with the single lip away from the pipe end.
Slide the coupling over the reducer and snug the clamps to hold it in place.
Push the large pipe into the other end of the coupling.
Tighten the coupling clamps to 120 in-lb, and any shield clamps to 60 in-lb. Bed and support the pipe, then inspect and test before backfilling.
Couplings with two reducer bushings have their own install sheet, in Documents below.
| Sizes | Engineered to the measured O.D. of each pipe |
| Part numbers | LDC followed by the pipe O.D.s, for example LDC 44.00x38.30 |
| Pipe materials | Clay, concrete, cast and ductile iron, plastic or fiberglass |
| Versions | Non-shielded, or Strong Back RC with a stainless steel shield |
| Body | Flexible PVC, 10″ wide |
| Clamps | High torque stainless steel with multiple take-up points |
| Installation torque | 120 in-lb on the coupling clamps. 60 in-lb on shield clamps, if supplied. |
| Reducer bushings | For O.D. differences from 1¼″ to 12″ |
| Maximum operating temperature | 140°F, non-continuous |
| Minimum operating temperature | −30°F |
| Standard | ASTM D5926 |
| Ordering | No minimum order. Custom parts are non-refundable. |
Installation instructions, an example submittal, custom build drawings and the catalog page.
All part numbers
Open any part for its specs, dimensional drawing and documents.
No part number matches.
Whether it’s sizing, an odd fitting or a tricky tie-in, our team can help. Reach out, or find your Fernco rep.